The switching performances of several improved silver tin-oxide materials with some kinds of additives, including WO
Rong Mingzhe;Wang Qiping
Electrical Contacts Proceedings of the Annual Holm Conference on Electrical Contacts
1993
Zhang J. M.;Wang Q. P.;Rong M. Z.
Diangong Jishu Xuebao Transactions of China Electrotechnical Society
2001
Wang Xiao-Hua;Rong Ming-Zhe;Jia Shen-Li;Meng Yong-Peng;Li Kun;Ma Qiang
Gaoya Dianqi High Voltage Apparatus
2003
A new magnetic hydro-dynamics (MHD) model of arc in H.V. auto-expansion SF
Rong Ming-Zhe;Yang Qian;Fan Chun-Duo
Zhongguo Dianji Gongcheng Xuebao Proceedings of the Chinese Society of Electrical Engineering
2004
Zheng Yi;Xu Yu-Yu;Wang Xiao-Hua;Rong Ming-Zhe
Gaoya Dianqi High Voltage Apparatus
2004
The dielectric barrier corona discharge (DBCD) in a wire-cylinder configuration and the dielectric barrier discharge (DBD) in a coaxial cylinder configuration are investigated, then the dissipated power and gas gap voltage are calculated by analyzing the measured Lissajous figure. The researching results demonstrate that the discharge current in DBD has higher pulse amplitude than in DBCD, and with the increasing applied voltage, the energy utilization factor for SO
Sun Yanzhou;Qiu Yuchang;Rong Mingzhe;Yuan Xingcheng
Hsi an Chiao Tung Ta Hsueh Journal of Xi an Jiaotong University
2004
NO
Liu Jingjing;Yuan Zhibing;Yuan Xingcheng;Rong Mingzhe
Gaodianya Jishu High Voltage Engineering
2005
A new magnetic hydro-dynamics (MHD) model of arc in H.V. auto-expansion SF
Rong Mingzhe;Yang Qian;Fan Chunduo
Plasma Science and Technology
2005
Based on a magnetohydrodynamic model, a numerical simulation of high-current vacuum arc (HCVA) is carried out. In this model, the kinetic energy terms and ion viscosity terms in energy conservation equations are considered. Compared with the supersonic constricted vacuum arc, the ion flow in HCVA is in the subsonic status. Therefore, boundary conditions of cathode and anode sides have to be adjusted for HCVA. According to the simulation results of HCVA, we can find that the maximal plasma pressure appears near the cathode side. The characteristics of HCVA are significantly different from those of supersonic vacuum arc. Then, we make the comparisons between simulation results and experimental results (such as electron number density, electron temperature, ion temperature, high speed charge-coupled device photographs, and so on). The simulation results are in agreement with the experimental results. In addition, we also analyze the influence of different arc models on the distribution of current density in the anode side. © 2006 American Institute of Physics.
Wang Lijun;Jia Shenli;Shi Zongqian;Rong Mingzhe
Journal of Applied Physics
2006
High voltage circuit breaker is one of the key parts of power system, quick fault diagnosis of circuit breaker is of important to the quick discover of the fault cause, solve the fault source, and make sure the rapidly recovery of power system. In this paper, an improved algorithm of general radial basis function neural network (RBFNN) is introduced, based on improved algorithm, the neural network realizes quick fault diagnosis and self-refresh of neural network, and the neural network is applied to the on-line fault diagnosis expert system. The expert system deal with the fault data that sent from on-line monitoring equipment by using neural network, and can discover the fault type and give reasonable solution by forward reasoning. Meanwhile, the expert system has the ability of achieving new knowledge based on the application of self-refresh ability of RBF neural network.
Wang Xiao-Hua;Rong Ming-Zhe;Wu Yi;Liu Ding-Xin
Zhongguo Dianji Gongcheng Xuebao Proceedings of the Chinese Society of Electrical Engineering
2007