Eric D. Bateman;Helen K. Reddel;Paul M. O’Byrne;Peter J. Barnes;南山 钟;Christina Keen;Carin Jorup;Rosa Lamarca;Agnieszka Siwek-Posluszna;J. Mark FitzGerald
University of Cape Town;University of Sydney;Michael G. DeGroote School of Medicine;Imperial College London;Guangzhou Medical College;AstraZeneca;University of British Columbia
发表时间:2018-5-17
期 刊:New England Journal of Medicine
语 言:English
U R L: http://www.scopus.com/inward/record.url?scp=85047300745&partnerID=8YFLogxK
BACKGROUND Patients with mild asthma often rely on inhaled short-acting β2-agonists for symptom relief and have poor adherence to maintenance therapy. Another approach might be for patients to receive a fast-acting reliever plus an inhaled glucocorticoid component on an as-needed basis to address symptoms and exacerbation risk. METHODS We conducted a 52-week, double-blind, multicenter trial involving patients 12 years of age or older who had mild asthma and were eligible for treatment with regular inhaled glucocorticoids. Patients were randomly assigned to receive twice-daily placebo plus budesonide–formoterol (200 μg of budesonide and 6 μg of formoterol) used as needed or budesonide maintenance therapy with twice-daily budesonide (200 μg) plus terbutaline (0.5 mg) used as needed. The primary analysis compared budesonide–formoterol used as needed with budesonide maintenance therapy with regard to the annualized rate of severe exacerbations, with a prespecified noninferiority limit of 1.2. Symptoms were assessed according to scores on the Asthma Control Questionnaire–5 (ACQ-5) on a scale from 0 (no impairment) to 6 (maximum impairment). RESULTS A total of 4215 patients underwent randomization, and 4176 (2089 in the budesonide–formoterol group and 2087 in the budesonide maintenance group) were included in the full analysis set. Budesonide–formoterol used as needed was noninferior to budesonide maintenance therapy for severe exacerbations; the annualized rate of severe exacerbations was 0.11 (95% confidence interval [CI], 0.10 to 0.13) and 0.12 (95% CI, 0.10 to 0.14), respectively (rate ratio, 0.97; upper one-sided 95% confidence limit, 1.16). The median daily metered dose of inhaled glucocorticoid was lower in the budesonide–formoterol group (66 μg) than in the budesonide maintenance group (267 μg). The time to the first exacerbation was similar in the two groups (hazard ratio, 0.96; 95% CI, 0.78 to 1.17). The change in ACQ-5 score showed a difference of 0.11 units (95% CI, 0.07 to 0.15) in favor of budesonide maintenance therapy. CONCLUSIONS In patients with mild asthma, budesonide–formoterol used as needed was noninferior to twice-daily budesonide with respect to the rate of severe asthma exacerbations during 52 weeks of treatment but was inferior in controlling symptoms. Patients in the budesonide–formoterol group had approximately one quarter of the inhaled glucocorticoid exposure of those in the budesonide maintenance group. (Funded by AstraZeneca; SYGMA 2 ClinicalTrials.gov number, NCT02224157.
Scopus度量
年份 | CiteScore | SJR | SNIP |
---|---|---|---|
1996 | |||
1997 | |||
1998 | |||
1999 | 7.361 | 10.989 | |
2000 | 8.367 | 10.43 | |
2001 | 8.571 | 10.65 | |
2002 | 9.315 | 11.39 | |
2003 | 10.407 | 13.878 | |
2004 | 11.349 | 13.963 | |
2005 | 9.888 | 12.13 | |
2006 | 10.173 | 11.886 | |
2007 | 10.481 | 11.853 | |
2008 | 11.386 | 11.487 | |
2009 | 11.765 | 11.932 | |
2010 | 13.149 | 11.382 | |
2011 | 56 | 13.674 | 12.685 |
2012 | 60.2 | 13.984 | 13.287 |
2013 | 58 | 14.796 | 14.706 |
2014 | 57.3 | 16.259 | 13.935 |
2015 | 57.4 | 16.591 | 13.011 |
2016 | 61.1 | 18.009 | 12.685 |
2017 | 67.2 | 19.476 | 12.908 |
2018 | 73.1 | 19.524 | 13.73 |
2019 | 66.1 | 18.291 | 13.212 |
2020 | 76.1 |
相似文献推荐